  "schemaVersion": "0.2.0",
  "auditScope": "https://solar.lowtechmagazine.com",
  "scopeValidatorSHA256": "5e2ec830860341ebef9a66ff45d9dbbf1c3c5e0ac74f8a603ba9301688c5606f",
  "sourceSHA256": {
    "staged": "5e0b909dddc2ef59dd2ca33c6269eff4234a9af754f1ec48917abef50e271e2a",
    "traffic": "d7d5606a51e2316e395333b007de2108fff6312946203a35fb881be46657201f",
    "energy": "a6a5365a585a8796a2c03d45c8cef5e7960821f7eca4072025f9dae4aafba0b9"
  },
  "calculatorSHA256": "67ae055f01459f2962320088180f9ee48e9cf820bc9c123e45145cb4c388c075",
  "energyValidatorSHA256": "ce1445b9962919eb3d025ac6b8514ce7b40abb44297aaf1bad7ff3f4b57e0c25",
  "dependencyLockSHA256": "ec953293d1f0ba8dccd1585b196daddb52b351b47f4c6d52958c794088f0519e",
  "model": "CO2.js 0.19.0 / SWDM v4, global model electricity factors, no DCR assigned by this scenario calculator",
  "visitSelection": "first",
  "clientGridIntensity": 494.0,
  "trafficDatasetMonth": "202609",
  "scenarios": [
    {
      "site": "https://solar.lowtechmagazine.com",
      "basis": "scenario",
      "unit": "kgCO2e/year",
      "status": "estimated",
      "value": 16.728628477903456,
      "functionalUnit": "One estimated year of page views at the audited origin, modeled operational and embodied browsing emissions",
      "notIncluded": "Not a complete organizational footprint; no site-specific backend/build/office inventory or remote inference energy",
      "assumptions": {
        "pageMix": "Equal weights across sampled page URLs",
        "visitSelection": "First recorded initial visit per URL",
        "realPageMix": "unknown",
        "visitMix": "100% first visits, 0% returning visits",
        "hosting": "unknown; model uses non-green scenario",
        "traffic": "Rank-bucket cohort estimate, not actual analytics",
        "sensitivity": "All views at the minimum/maximum sampled page intensity; not a confidence interval or bounds on true site emissions"
      },
      "annualPageviews": 572851.0,
      "gramsPerViewProxy": 0.029202407742857144,
      "rankBucket": 5000000,
      "transferInputs": "complete_within_protocol",
      "pages": [
        {
          "url": "https://solar.lowtechmagazine.com/",
          "gramsPerView": 0.0718753698,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/",
              "runId": "home-no_banner",
              "bytes": 484989,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0718753698,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 484989,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/archives/",
          "gramsPerView": 0.0054164136,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/archives/",
              "runId": "archive-no_banner",
              "bytes": 36548,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0054164136,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 36548,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/about/the-solar-website/",
          "gramsPerView": 0.0192314694,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/about/the-solar-website/",
              "runId": "solar-methodology-no_banner",
              "bytes": 129767,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0192314694,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 129767,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/power/",
          "gramsPerView": 0.0059638644,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/power/",
              "runId": "power-no_banner",
              "bytes": 40242,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0059638644,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 40242,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/offline-reading/",
          "gramsPerView": 0.0579823608,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/offline-reading/",
              "runId": "offline-reading-no_banner",
              "bytes": 391244,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0579823608,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 391244,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/2025/10/how-to-build-a-solar-powered-electric-oven/",
          "gramsPerView": 0.0411658104,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/2025/10/how-to-build-a-solar-powered-electric-oven/",
              "runId": "solar-oven-no_banner",
              "bytes": 277772,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0411658104,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 277772,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        },
        {
          "url": "https://solar.lowtechmagazine.com/privacy/",
          "gramsPerView": 0.0027815658,
          "accountingStatus": "complete",
          "branches": [
            {
              "url": "https://solar.lowtechmagazine.com/privacy/",
              "runId": "privacy-no_banner",
              "bytes": 18769,
              "accountingStatus": "complete_within_protocol",
              "trace": {
                "co2": 0.0027815658,
                "green": false,
                "variables": {
                  "description": "Below are the variables used to calculate this CO2 estimate.",
                  "bytes": 18769,
                  "gridIntensity": {
                    "description": "The grid intensity (grams per kilowatt-hour) used to calculate this CO2 estimate.",
                    "device": {
                      "value": 494
                    },
                    "dataCenter": {
                      "value": 494
                    },
                    "network": {
                      "value": 494
                    }
                  },
                  "greenHostingFactor": 0,
                  "dataReloadRatio": 0.02,
                  "firstVisitPercentage": 1,
                  "returnVisitPercentage": 0
                }
              }
            }
          ],
          "pageWeight": 0.14285714285714285
        }
      ],
      "sensitivityKgPerYear": {
        "lowestSampledPage": 1.5934227500958,
        "highestSampledPage": 41.1738774652998
      }
    }
  ],
  "clientEnergyScenarios": [
    {
      "site": "https://solar.lowtechmagazine.com",
      "status": "estimated",
      "basis": "scenario",
      "value": 6.4183893830317835,
      "unit": "kWh/year",
      "kgCO2ePerYear": 3.170684355217701,
      "gridIntensity": {
        "value": 494.0,
        "unit": "gCO2e/kWh",
        "basis": "Assumed comparison factor, not audience electricity data",
        "defaultFactorReference": "https://sustainablewebdesign.org/estimating-digital-emissions/"
      },
      "assumptions": {
        "pageMix": "Equal weights across energy-sampled URLs; median of three matching repetitions per URL",
        "visitMix": "Every estimated pageview repeats the recorded initial-load scenario on the tested device/browser",
        "boundary": "Modeled browser CPU, memory, disk and display operation only; excludes network, remote servers, embodied emissions and later reading/interaction",
        "measurement": "GreenFrame resource-counter model, not direct electricity metering",
        "improvement": "A proportional reduction is a sensitivity scenario, not demonstrated achievable savings",
        "additivity": "Overlaps SWDM device scope; do not add these estimates to SWDM"
      },
      "annualPageviews": 572851.0,
      "rankBucket": 5000000,
      "WhPerViewProxy": 0.011204291138588889,
      "sampledPageCount": 2,
      "auditedPageCount": 7,
      "pages": [
        {
          "url": "https://solar.lowtechmagazine.com/",
          "WhPerView": 0.011028266190233333,
          "pageWeight": 0.5
        },
        {
          "url": "https://solar.lowtechmagazine.com/2025/10/how-to-build-a-solar-powered-electric-oven/",
          "WhPerView": 0.011380316086944444,
          "pageWeight": 0.5
        }
      ]
    }
  ],
  "sensitivity": {
    "reductionFraction": 0.1,
    "meaning": "Hypothetical 10% reduction in per-view intensity at unchanged traffic; not a forecast of achievable savings"
  }
}